In short:
- When office access control fails, magnetic locks and other fail-safe devices release, fail-secure electric strikes stay locked from outside, and any ordinary mechanical lock or key override on the door keeps working.
- Work out which kind of electric lock each door has. That tells you which doors are now open, which are stuck, and which a key still controls.
- Readers, controllers, software, wiring and power supplies go to the company that installed the system. Mechanical locks, cylinders, key overrides and keys are a locksmith's job.
- Never wedge, chain or padlock an escape door to make up for failed electronics. People must still be able to get out.
- Know where every key override is, and who holds those keys, before the next failure.
What still locks when office access control fails?
An access-control system is a layer of electronics on top of a door. A card reader, keypad, fingerprint reader or phone app sends a signal to a controller, which switches power to an electric lock. When any part of that chain fails, whether the reader, the controller, the network, the software or the power, the door falls back to whatever its electric lock does without a signal. And that depends entirely on how the lock was specified.
The two terms that matter are fail-safe and fail-secure. Allegion, a door hardware maker, defines them simply: a fail-safe device is unlocked when power is removed, and power is applied to keep it locked; a fail-secure device stays locked when power is removed, and power is applied to unlock it. The terms describe the secure, outside face of the door.
Allegion's point about free egress is the reassuring part: most electrified hardware still lets people leave from the inside whether it is fail-safe or fail-secure. The usual exception is the electromagnetic lock, which has no handle of its own and relies on separate release devices. So a failure normally affects getting in more than getting out, but you should check every door rather than assume.
How can you tell which kind of electric lock a door has?
You can often tell by looking, without touching any wiring. The table covers the common types in offices, warehouses and shops.
| Device | What it looks like | Without power | What still works mechanically |
|---|---|---|---|
| Magnetic lock (maglock) | A long rectangular block on the frame head, with a steel plate on the door that meets it | Releases: fail-safe by design. The door is held only by its closer. | Any separate mechanical lock or latch fitted to the door |
| Electric strike | A strike plate in the frame where the latch goes, usually with a wire into the frame | Usually fail-secure: stays locked from outside. Some are fitted fail-safe. | The door's own lock and handle; from inside, the handle normally still opens it |
| Electrified mortice or solenoid lock | Looks like an ordinary lever lock; the wire runs inside the door through a hinge or cable loop | Either type, depending on how it was ordered | Usually a key cylinder on the outside acting as an override |
| Turnstile or speed gate | Free-standing barrier in a foyer | Depends on the product and settings | A manual or emergency release, normally operated by building security |
The Wikipedia article on electric strikes notes that with a fail-secure strike, the door's mechanical lock can still be used from the inside so people can exit. The article on electromagnetic locks explains why maglocks are fail-safe: an electromagnet holds a steel plate on the door, and cutting the current releases it.
Where are the electric and mechanical parts on a typical office door?
What should you check before calling anyone?
These checks are about observation. Don't open controller boxes, pull wires or remove covers: apart from the risk, it may affect the installer's warranty and the building's fire-safety setup.
- One door or every door? If every reader is dark, suspect power, the controller or the network. If one door misbehaves, suspect that door's reader, lock or alignment.
- Are the readers lit? A dark reader points to power. A lit reader that beeps "denied" points to software or the card list.
- Is the building's power on? A power cut or a tripped circuit explains a lot. If it's scheduled load-shedding, our article on electronic locks during load-shedding covers what to expect.
- Has the fire alarm triggered? Many systems are wired to release certain doors on a fire alarm. If the alarm panel shows an event, that is for the fire-alarm company and building management.
- Is there a key override? Look for a key cylinder on the outside of the door or on the lock. Find out who holds that key.
- Does the door close fully? A door that has dropped, or a closer that no longer pulls it shut, can stop a strike from catching or a maglock plate from meeting the magnet. That's mechanical and worth noting.
Who fixes what: the installer or a locksmith?
Splitting the job correctly saves time and money. We deal with the mechanical lock, the key and the manual release. Electrical faults go to whoever installed the access-control system.
| Problem | Who to call |
|---|---|
| Readers dead, cards rejected, software or app not working | Access-control installer or maintenance company |
| Maglock not holding, strike not releasing on a valid card | Access-control installer |
| Power supply, backup battery or wiring fault | Access-control installer or electrician |
| Key override cylinder stiff, broken or key lost | Locksmith |
| Mechanical lock or handle broken, latch not retracting | Locksmith |
| Locked out of an office with no working override | Locksmith, with proof of the company's authority |
| Fire alarm releasing or holding doors | Fire-alarm company and building management |
Our commercial locksmith service covers office, warehouse and shop locks, including mechanical overrides and cylinders. Where an override lock is worn or seized, lock repair may be enough; where keys are unaccounted for, changing the cylinder is usually the sensible step.
Is it safe to leave the doors like that until it's fixed?
That depends on which way the doors have failed.
Doors that have released (maglocks, fail-safe devices) leave the premises open. Allegion notes this as the trade-off of fail-safe hardware: a security risk during a power failure or fire alarm. If the building is occupied, a person at reception or at the main entrance is the simplest stopgap. If the door also has an ordinary mechanical lock, it can be locked with a key at closing time, as long as the door is not a required escape route and everyone inside can still get out.
Doors that have stayed locked (fail-secure strikes) keep people out but should still let people leave. Check that each one really does open from the inside.
Never chain, padlock or wedge an escape door to make up for failed electronics, and never prop a fire door open. South Africa's fire-protection requirements under the National Building Regulations (SANS 10400 Part T) cover escape routes and exit doors, and obstructing an escape route is an offence. If you are not sure whether a door is part of an escape route, ask building management or a fire-safety professional before changing how it locks.
How do you prepare for the next access-control failure?
- Make a simple list of every controlled door: what electric lock it has, whether it is fail-safe or fail-secure, and whether it has a key override.
- Put override keys on a signed key register, and keep them where at least two people can reach them after hours. Our article on the lock checklist for a new office lease covers this when you move in.
- Ask the installer whether the system has backup power, how long it is expected to last, and when the batteries were last tested.
- Give rooms that must stay locked, such as a server room, a mechanical lock as well. See server room and comms cabinet locks.
- Agree with the park or building how a locksmith or installer gets in after hours. Our guide to getting a locksmith through park security has a checklist.
- Keep the installer's after-hours number with the override keys, not only in someone's phone.
What helps when you book a locksmith for an office door?
Send photos before the visit: the whole door, the lock and handle close up, any cylinder or keyhole, the frame where the latch goes, and the electric device if there is one. Tell us who can authorise the work for the company and how the technician gets through the park and building security.
As a fully mobile mobile locksmith in Midrand, we come to offices, warehouses and shops 24/7. There's an R250 call-out, the technician quotes on site before any work starts, and nothing is done until you agree. Non-destructive entry is tried first, and we ask for proof of authority before opening any business premises. Payment is by EFT, cash or card.
Questions
Will a magnetic lock open during a power cut?
Normally yes. Maglocks are fail-safe: they need current to hold, and release when it stops. If the system has backup batteries, the lock may keep holding until those run down. Ask your installer how your system is set up.
Can a locksmith fix our card readers or access-control software?
No. Readers, controllers, software, wiring and power supplies belong with the company that installed the system. We handle the mechanical side: locks, cylinders, key overrides, keys and manual releases.
Our office is locked and nobody has an override key. What now?
Call a locksmith with someone who can authorise the work for the company. Non-destructive entry is tried first, and we ask for proof of the company's authority before opening. Afterwards, consider changing the override cylinder if its keys can't be accounted for.
Should every access-controlled door have a key override?
Not necessarily, but you should know which ones do and which don't. The right answer for each door depends on its use and whether it's on an escape route. Agree it with the installer and building management, and keep the override keys under control.
Need a locksmith to look at it?
If this hasn't solved the problem, our commercial locksmith service covers it. We're a mobile locksmith in Midrand, so we come to your door.
Sources and further reading
- Allegion: Fail safe vs. fail secure — definitions; most electrified hardware allows free egress; maglocks need separate release devices; strikes usually fail secure; fail-safe doors are a security risk in a power failure
- Wikipedia: Electric strike — fail-secure and fail-safe strikes; with a fail-secure strike the mechanical lock can still be used from inside
- Wikipedia: Electromagnetic lock — maglocks hold a steel plate with an electromagnet, are fail-safe and release without power; separate release devices; battery backup
- SANS 10400: What Part T, Fire Protection, says — Part T covers exit doors and escape routes; obstructing escape routes in buildings is an offence